×

Productos

    Abrir menu

    HIPLUS AIRE ACONDICIONADO, S.L.

    C. Masía Torrents, 2
    08800 VILANOVA I LA GELTRÚ (Barcelona)

    REQUEST A QUOTE/INFORMATION
    X
    Visualizar en modo Listado Visualizar en modo Cuadrícula
    4 productos.
    20 - Water terminal unit, wall mounted fan coil FPW

    GENERAL The FPW water fan coils are used for cooling and heating applications, for small and large rooms. This fan coils are equipped with ionization systems: a flashover inside the unit is transmitted to carbon fibres which produce negative ions. This devise purifies the air neutralizing the microbes. TANGENTIAL FANS Selected for high air volumes at low speeds to guarantee a low noise level. WATER COIL Made of copper tubes mechanically expanded into aluminium fins. The headers are equipped with female fittings (GAS theads) and easily accessible air vents. CABINET Moderm and elegant design made to avoid corrosion, bleds easily. WORKING LIMITS: • Maximum water temperature 80 oC. • Maximum working pressure 10 Bar. AIR FLOW The Airflow deflector opens and closes automatically when the unit is turned on or switched off. The very low noise airflow can be adjusted manually to the right or left. The high/low adjustment of the airflow in 5 different positions is made by an infrared remote control. A BETTER AIR FLOW • In cooling mode, the supply air deflector swings up thus avoiding the airflow being directed to the lower part of the room. • In heating mode the supply air deflector swings down to distribute the hot air uniformly in the lower parts of the room. STANDARD ACCESSORIES • Air filter • Ionizator (only models FPW 1 and FPW 2) • Swing motorized supply air deflector • Infrared remote control with display • Function automatic or manual • Fan speed automatic • Minium low water temperature sensor • Wall hook brackets

    PDF
    25 - Water terminal unit, wall mounted fan coil FPW

    GENERAL The FPW water fan coils are used for cooling and heating applications, for small and large rooms. This fan coils are equipped with ionization systems: a flashover inside the unit is transmitted to carbon fibres which produce negative ions. This devise purifies the air neutralizing the microbes. TANGENTIAL FANS Selected for high air volumes at low speeds to guarantee a low noise level. WATER COIL Made of copper tubes mechanically expanded into aluminium fins. The headers are equipped with female fittings (GAS theads) and easily accessible air vents. CABINET Moderm and elegant design made to avoid corrosion, bleds easily. WORKING LIMITS: • Maximum water temperature 80 oC. • Maximum working pressure 10 Bar. AIR FLOW The Airflow deflector opens and closes automatically when the unit is turned on or switched off. The very low noise airflow can be adjusted manually to the right or left. The high/low adjustment of the airflow in 5 different positions is made by an infrared remote control. A BETTER AIR FLOW • In cooling mode, the supply air deflector swings up thus avoiding the airflow being directed to the lower part of the room. • In heating mode the supply air deflector swings down to distribute the hot air uniformly in the lower parts of the room. STANDARD ACCESSORIES • Air filter • Ionizator (only models FPW 1 and FPW 2) • Swing motorized supply air deflector • Infrared remote control with display • Function automatic or manual • Fan speed automatic • Minium low water temperature sensor • Wall hook brackets

    PDF
    35 -Water terminal unit, wall mounted fan coil FPW

    GENERAL The FPW water fan coils are used for cooling and heating applications, for small and large rooms. This fan coils are equipped with ionization systems: a flashover inside the unit is transmitted to carbon fibres which produce negative ions. This devise purifies the air neutralizing the microbes. TANGENTIAL FANS Selected for high air volumes at low speeds to guarantee a low noise level. WATER COIL Made of copper tubes mechanically expanded into aluminium fins. The headers are equipped with female fittings (GAS theads) and easily accessible air vents. CABINET Moderm and elegant design made to avoid corrosion, bleds easily. WORKING LIMITS: • Maximum water temperature 80 oC. • Maximum working pressure 10 Bar. AIR FLOW The Airflow deflector opens and closes automatically when the unit is turned on or switched off. The very low noise airflow can be adjusted manually to the right or left. The high/low adjustment of the airflow in 5 different positions is made by an infrared remote control. A BETTER AIR FLOW • In cooling mode, the supply air deflector swings up thus avoiding the airflow being directed to the lower part of the room. • In heating mode the supply air deflector swings down to distribute the hot air uniformly in the lower parts of the room. STANDARD ACCESSORIES • Air filter • Ionizator (only models FPW 1 and FPW 2) • Swing motorized supply air deflector • Infrared remote control with display • Function automatic or manual • Fan speed automatic • Minium low water temperature sensor • Wall hook brackets

    PDF
    40 - Water terminal unit, wall mounted fan coil FPW

    GENERAL The FPW water fan coils are used for cooling and heating applications, for small and large rooms. This fan coils are equipped with ionization systems: a flashover inside the unit is transmitted to carbon fibres which produce negative ions. This devise purifies the air neutralizing the microbes. TANGENTIAL FANS Selected for high air volumes at low speeds to guarantee a low noise level. WATER COIL Made of copper tubes mechanically expanded into aluminium fins. The headers are equipped with female fittings (GAS theads) and easily accessible air vents. CABINET Moderm and elegant design made to avoid corrosion, bleds easily. WORKING LIMITS: • Maximum water temperature 80 oC. • Maximum working pressure 10 Bar. AIR FLOW The Airflow deflector opens and closes automatically when the unit is turned on or switched off. The very low noise airflow can be adjusted manually to the right or left. The high/low adjustment of the airflow in 5 different positions is made by an infrared remote control. A BETTER AIR FLOW • In cooling mode, the supply air deflector swings up thus avoiding the airflow being directed to the lower part of the room. • In heating mode the supply air deflector swings down to distribute the hot air uniformly in the lower parts of the room. STANDARD ACCESSORIES • Air filter • Ionizator (only models FPW 1 and FPW 2) • Swing motorized supply air deflector • Infrared remote control with display • Function automatic or manual • Fan speed automatic • Minium low water temperature sensor • Wall hook brackets

    PDF
    ×
    Filtros
    Visualizar en modo Cuadrícula Visualizar en modo Listado
    anterior
    página de
    siguiente
    Las cookies nos permiten ofrecer nuestros servicios de forma más rápida y personalizada. Al acceder y continuar navegando en esta web acepta el uso de cookies. Para más información, lea nuestra Política de cookies
    Aceptar
    X

    Suscríbete!

    56.000 usuarios

    ya reciben toda la actualidad de la
    Arquitectura, Ingeniería y Construcción

    SUSCRÍBETE