×

Productos

    Abrir menu

    SISTEMAS TECNICOS DEL ACCESORIO Y COMPONENTES SL

    Polígono industrial Picusa
    La Matanza s/n
    15900 PADRÓN (A Coruña)
    REQUEST A QUOTE/INFORMATION
    X
    Visualizar en modo Listado Visualizar en modo Cuadrícula
    19 productos.
    STACBOND®FR STB-CH ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE:(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10-20 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.013 SCH-4) with anti-vibration rubber buffers.

    PDF
    Panel STACBOND®PE ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels . The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2).Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE:(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.013 SCH-4) with anti-vibration rubber buffers.

    PDF
    Panel STACBOND®A2 STB-CH ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE:(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10-20 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.013 SCH-4) with anti-vibration rubber buffers.

    PDF
    STACBOND®FR STB-SZ ventilated facade system - 4mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE:(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "Omega" profile. If the calculations show a need reinforcement, this will be using extruded "L" profiles (ref. 05.99.231) screwed to all Omegas and glued to the panels using Sikatack-Panel adhesive (or similar).

    PDF
    STACBOND®PE STB-SZ ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels. The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE:(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "Omega" profile. If the calculations show a need reinforcement, this will be using extruded "L" profiles (ref. 05.99.231) screwed to all Omegas and glued to the panels using Sikatack-Panel adhesive (or similar).

    PDF
    STACBOND®A2 STB-SZ ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE :(The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "Omega" profile. If the calculations show a need reinforcement, this will be using extruded "L" profiles (ref. 05.99.231) screwed to all Omegas and glued to the panels using Sikatack-Panel adhesive (or similar).

    PDF
    STACBOND®FR STB riveted-screwed ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.020 SCR-3) and levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®PE STB - riveted-screwed ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels. The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.020 SCR-3) and levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®A2 STB - riveted-screwed ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy Omega profiles (Ref. 05.19.003 SCH-2), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.020 SCR-3) and levelled via double T anchors (Ref.05.19.004 SCH-1) and/or U anchors (Ref.05.19.046).

    PDF
    STACBOND®FR STB-T-SZ ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy "T" profiles ((Ref. 05.19.043 ST-3), levelled via intermediary "L"-shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "T" profile. If the calculations show a need reinforcement, this will be using extruded "Z" profiles (ref. 05.19.049) screwed to all T-profiles and glued to the panels using Sikatack-Panel adhesive (or similar). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®PE STB-T-SZ ventilated facade system

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels. The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy "T" profiles ((Ref. 05.19.043 ST-3), levelled via intermediary "L"-shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "T" profile. If the calculations show a need reinforcement, this will be using extruded "Z" profiles (ref. 05.19.049) screwed to all T-profiles and glued to the panels using Sikatack-Panel adhesive (or similar). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®A2 STB-T-SZ ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy "T" profiles ((Ref. 05.19.043 ST-3), levelled via intermediary "L"-shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92); panels are fixed to the profiles on upper and lower parts to the profiles (Ref.05.19.001 SC-S and Ref.05.19.002 SC-Z); the "Z" profile is fixed at a later time to the "T" profile. If the calculations show a need reinforcement, this will be using extruded "Z" profiles (ref. 05.19.049) screwed to all T-profiles and glued to the panels using Sikatack-Panel adhesive (or similar).

    PDF
    STACBOND®FR STB-T - riveted-screwed ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-T-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T- profiles(Ref. 05.19.043 ST-3), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.021) and levelled via "L" shaped anchors (Ref.05.19.042 ST-2-68; 05.19.045 ST2-92). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®PE STB-T- riveted-screwed ventilated facade system

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels. The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-T-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T- profiles(Ref. 05.19.043 ST-3), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.021) and levelled via "L" shaped anchors (Ref.05.19.042 ST-2-68; 05.19.045 ST2-92). Products and installation in accordance with DIT 553p/16, ETE 15/0655 (European Technical Assessment) with CE Marking.

    PDF
    STACBOND®A2 STB-T - riveted ventilated facade system

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 5-20 mm slots between sheets via an STB-T-RIVETED system composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T- profiles(Ref. 05.19.043 ST-3), in vertical and/or horizontal, fastened together using junction pieces (Ref. 05.19.021) and levelled via "L" shaped anchors (Ref.05.19.042 ST-2-68; 05.19.045 ST2-92).

    PDF
    STACBOND®FR STB-T-CH ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® FR aluminium composite panels (Fire rating B-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density, fire retardant core (total weight approx. 8.02 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 5.62 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 29 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10-20 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T-Omega profiles (Ref. 05.19.061 profile T-Ω), levelled via "L" shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92, 05.19.051 ST-1-116 a 05.19.056 ST-1-236); panels are fixed to the omega profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.062 CUELGUE STB-T-CH) with anti-vibration rubber buffers.

    PDF
    STACBOND®PE STB-T-CH ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® PE aluminium composite panels. The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with a 3 mm intermediate, low density polyethylene core (total weight approx. 5.50 kg/m2).External face:5005 aluminium alloy in accordance with UNE-EN 485-2; Thermal transmission 3.38 W/m²K, Sound Reduction Index (UNE-EN ISO 140-3:1995) Rw (C;Ctr) (dB), 26 (0;-2). Exterior face of aluminium lacquered (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10-20 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T-Omega profiles (Ref. 05.19.061 profile T-Ω), levelled via "L" shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92, 05.19.051 ST-1-116 a 05.19.056 ST-1-236); panels are fixed to the omega profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.062 CUELGUE STB-T-CH) with anti-vibration rubber buffers.

    PDF
    STACBOND®A2 STB-T-CH ventilated facade system - 4 mm

    Supply and installation of external wall facing based on 4mm (total thickness) STACBOND ® A2 aluminium composite panels (Fire rating A2-s1-d0). The panels are composed of a double layer of 0.5 mm sheet aluminium (exterior and interior face) in accordance with EN 485-4:1993 with an intermediate, high mineral content core (total weight approx. 8.02 kg/m2). Exterior face of 5005 aluminium alloy in accordance with UNE-EN 485-2; lacquered on exterior face (22/40 thickness), colour to be defined by project management and finished with PVdF Kynar 500 70/30 (70% polyvinylidene fluoride, 30% acrylic resin) with 100 µ protective plastic film. Interior face of aluminium lacquered. The pre-treatments used for both aluminium faces are chromium free. Standard system for attaching panels to substructure and / or with stiffeners depending on the dimensions of the components, attached to the panels with a Sikatack-Panel adhesive system (or similar). The building envelope is completed with trim for lintels, sills, jambs, thresholds and specific elements via the manufacture of special parts composed of the same panels and with joints to allow free expansion. Sill trims have a minimum fall of 17% (10º) in accordance with Code. SUBSTRUCTURE: (The harshness of the environment must be taken into account in accordance with Code SE-AE Wind Effect to calculate the Velocity Pressure Exposure Coefficient). Installed with vertical and/or horizontal modulation, leaving 10-20 mm slots between sheets via a system of sheets composed of an auxiliary support structure of extruded 6063 T5/T6 aluminium alloy T-Omega profiles (Ref. 05.19.061 profile T-Ω), levelled via "L" shaped anchors (Ref.05.19.041 ST-1-68; 05.19.044 ST-1-92, 05.19.051 ST-1-116 a 05.19.056 ST-1-236); panels are fixed to the omega profiles on upper part and hung by the recesses on the hanging supports (Ref. 05.19.062 CUELGUE STB-T-CH) with anti-vibration rubber buffers.

    PDF
    ×
    Filtros
    Visualizar en modo Cuadrícula Visualizar en modo Listado
    anterior
    página de
    siguiente
    Las cookies nos permiten ofrecer nuestros servicios de forma más rápida y personalizada. Al acceder y continuar navegando en esta web acepta el uso de cookies. Para más información, lea nuestra Política de cookies
    Aceptar
    X

    Suscríbete!

    56.000 usuarios

    ya reciben toda la actualidad de la
    Arquitectura, Ingeniería y Construcción

    SUSCRÍBETE